Crouse-Hinds Arktite® CPS732 201 1-Gang Angle Delayed Action Dead End Factory Sealed Receptacle Assembly, 125 to 250 VAC/480 VAC, 30 A
                                CPS732 201
                                    MFG #: CPS732 201
                                                            
                        
                                    
                                        $2,685.65
                                    
                                    
                                        / EA
                                    
                        
                            
                                Non-Stock Item
                            
                    - Manufacturer: Eaton
- Type: 1-Gang Angle Delayed Action Factory Sealed
- Series: CPS
- Voltage Rating: 125/250
- Amperage Rating: 30
- Horsepower: 3
- Frequency Rating: 60
- Number of Poles: 4
- Number of Wires: 3
- Terminal Type: Pressure Wired
- Material: Die Cast Aluminum
- Color: Natural
- Dimensions: 3-1/2 in L x 7-1/4 in W x 6-23/32 in H
- Brand: Crouse-Hinds
Crouse-Hinds Arktite® Receptacle Assembly, 1-Gang Angle Delayed Action Dead End Factory Sealed, Series: CPS, 125 to 250 VAC/480 VAC, 30 A, Pressure Wire Terminal, 3-1/2 in L x 7-1/4 in W x 6-23/32 in H Dimensions
                    - https://www.youtube.com/watch?v=G40Xq2oRNKE(YouTube)
- IDW_DOCUMENT_6f1427d1490065f92468161ec9b9293bcb48daf7ade738d8578ec07e44a2c59c.pdf()
- IDW_DOCUMENT_7008287bdd9ca7b120b82cfb4abc19d9f914fac151099020494f3eea1fec1b6d.pdf()
- IDW_DOCUMENT_8d1e8a7e623a7353cafa3941eaca8db03c55ce33cbc626f51989194fbc98800c.pdf()
- CPS receptacles are equipped with a rotating mechanism which prevents complete withdrawal of the CPP
- With portable electrically operated devices such as motor-generator sets, compressors, conveyors, po
- With portable electrically operated devices such as motor-generator sets, compressors, conveyors, po
- In locations which are hazardous due to the presence of flammable vapors or gases
- In petroleum refineries, chemical and petrochemical plants and other process industry facilities whe
- In damp or corrosive locations
- 3/8 to 7/8 in Dia cable
- 3/4 in hub
- Receptacles will take any of the plugs grouped in the bracket opposite the receptacle listings
- 3/8 to 7/8 in die cable
- Grounding style two through extra pole and shell
- Receptacles will take any of the plugs grouped in the bracket opposite the receptacle listings
- 7A, 1 hp, 480 VAC, CSA certified units are rated at 600 VAC at 7 A
- Style 2 grounded through extra pole and shell
                                    CPS receptacles are equipped with a rotating mechanism which prevents complete withdrawal of the CPP plug-in one continuous movement
                                
                                
                                    With portable electrically operated devices such as motor-generator sets, compressors, conveyors, portable tools, lighting systems and similar equipment
                                
                                
                                    With portable electrically operated devices such as motor-generator sets, compressors, conveyors, portable tools, lighting systems and similar equipment
                                
                                
                                    In locations which are hazardous due to the presence of flammable vapors or gases
                                
                                
                                    In petroleum refineries, chemical and petrochemical plants and other process industry facilities where similar hazards exist
                                
                                
                                    In damp or corrosive locations
                                
                                
                                    3/8 to 7/8 in Dia cable
                                
                                
                                    3/4 in hub
                                
                                
                                    Receptacles will take any of the plugs grouped in the bracket opposite the receptacle listings
                                
                                
                                    3/8 to 7/8 in die cable
                                
                                
                                    Grounding style two through extra pole and shell
                                
                                
                                    Receptacles will take any of the plugs grouped in the bracket opposite the receptacle listings
                                
                                
                                    7A, 1 hp, 480 VAC, CSA certified units are rated at 600 VAC at 7 A
                                
                                
                                    Style 2 grounded through extra pole and shell
                                
                        