GE Record Plus™ FBV26TE020RV Type FBV Molded Case Circuit Breaker, 600 VAC, 20 A, 35 kA at 480 VAC/65 kA at 240 VAC Interrupt, 2 Poles, Fixed Thermal Magnetic/LI Trip
FBV26TE020RV
MFG #: FBV26TE020RV
Requires Quote
Non-Stock Item
- Actuator Type: Toggle Handle
- Amperage Rating: 20 A
- Connection Type: Line/Load Lug
- Dimensions: 2.74 in W x 3.28 in D x 6.45 in H
- Frame: FB100
- Frequency Rating: 50/60 Hz
- Interrupt Rating: 35 kA at 480 VAC/65 kA at 240 VAC
- Manufacturer Name: ABB
- Mounting Type: Panel
- Number of Poles: 2
- Phase: 1
- Temperature Rating: -40 to 80 deg C
- Trip Type: Fixed Thermal Magnetic/LI
- Type: Type FBV
- Voltage Rating: 600 VAC
- Wire Size: 14 to 10 AWG
Record Plus™ represents the very latest in molded case circuit breaker design. Utilizing design features such as double break rotary contact structures and advanced ablative materials to enhance interruption, Record Plus™ is capable of interrupting ratings up to 200 kA (FC max is 150 kA). High kA ratings, selective coordination, reduced arc flash energy and current limitation embody the core design principles of Record Plus™. FC 100 circuit breakers are supplied with factory installed non-user interchangeable thermal magnetic trip units and can be supplied with or without lugs. FC is available in 2 and 3-pole versions, both in a 3-pole footprint. Record Plus™ product numbers ending in R or R0 do not include lugs. An R1 suffix indicates that the breaker is supplied with line and load lugs, R2 indicates load lugs and R3 indicates line lugs. RV suffixed product numbers include load lugs and line connections specifically designed for general electric Type AD panels. All frames use common internal accessories (auxiliary switches, UV releases, shunt trips and bell alarms) UL Listed for field installation.
- Application
- Item Features
- Standards
Commercial, Industrial, Current Limiting and Naval Applications
- Broad product line to meet virtually any application need
- Reduced downtime
- A tripped breaker is easily spotted and can be immediately reset after the fault has been corrected
- Eliminates single phasing
- A common trip bar disconnects all poles simultaneously on both overloads and short circuits
- Offers application flexibility through the use of a wide variety of accessory devices and special attachments
- Repetitive operation no fuses to replace
- Breakers can be repetitively tested
- Fuses must be destroyed to confirm calibration accuracy
- 35 kA at 480 VAC, 65 kA at 240 VAC interrupt rating
ARRA Compliant|Buy American Act Compliant|RoHS Compliant|UL 489 E11592|IEC 947-2|HACR Rated