GE TED134020 Type TED Core E Mid Tier Molded Case Circuit Breaker With Copper/Aluminum Load Lug, 480 VAC, 20 A, 18 kA Interrupt, 3 Poles, LI/Non-Interchangeable Thermal Magnetic Trip
TED134020
MFG #: TED134020
Requires Quote
Non-Stock Item
- Actuator Type: Pivot/Toggle Handle
- Amperage Rating: 20 A
- Connection Type: Load Lug
- Dimensions: 6-5/16 in H x 4-1/8 in W x 3-3/8 in D
- Frame: E150
- Frequency Rating: 50/60 Hz
- Interrupt Rating: 18 kA
- Manufacturer Name: ABB
- Material: Plastic
- Mounting Type: Bolted-On
- Number of Poles: 3
- Phase: 3
- Temperature Rating: 10 to 50 deg C
- Trip Type: LI/Non-Interchangeable Thermal Magnetic
- Type: Type TED Core E Mid Tier
- Voltage Rating: 480 VAC
- Wire Size: 12 to 10 AWG
The E150 product line consists of thermal magnetic circuit breakers, magnetic circuit breakers and molded case switches rated up to 150 A and 600 VAC. catalog numbers include the complete breaker or switch. the WL catalog number suffix indicates that the devices come with copper aluminum line and load lugs.
- Standards
- Application
- Item Features
UL 489 File No. E11592|CSA File No. LR57114|Federal Specification W-C-375
Industrial, Switchboards, Motor Control Centers and Lighting, Power and Customized Control Panelboards, Electrical Distribution and Control Applications
- Molded case is molded from high mechanical and high dielectric strength engineered plastic
- Trip indication is shown by handle position midway between ON and off to reset the trip mechanism, move the handle to extreme off then to ON position
- Quick-make, quick-break, trip-free mechanism minimizes arcing during breaker operation, contacts cannot be ''teased'' into position
- Trip-free mechanism is independent of manual handle control, the breaker trips under short circuit or overload, even though the operating handle is held in on position
- VERIFIERâ„¢ "twist-to-trip" and ''push-to-trip'' mechanically simulates over current tripping through actuation of linkages not operated by the on-off handle
- Common trip bar assures instant disconnect of all conductors when an overload or short circuit occurs on any one conductor in the circuit or an accessory trip device operates
- Silver alloy contacts combine the conductive properties of silver with other elements for clean, positive electrical contacting, pitting and burning are minimized for longer contact life
- Arc chutes of heat absorbing, insulating material and metal grid plates quickly ''extinguish'' arcs
- UL listed lugs for copper or aluminum cable, at full frame rating, easy access and simple, straight in wiring
- Proven reliability
- Provide cost effective solutions
- Multiple types to fit in your application
- 10 kA at 125 VDC, 10 kA at 250 VDC, 10 kA at 500 VDC, 14 kA at 600 VAC, 18 kA at 120/240 VAC, 18 kA at 240 VAC, 18 kA at 277 VAC, 18 kA at 480 VAC interrupt rating