Crouse-Hinds W2ST60354 W2ST Heavy Duty Non-Fusible Raintight Enclosed Switch, 120/240/480/600 VAC, 60 A, 3 hp, 7-1/2 hp, 15 hp, 20 hp, 25 hp, 30 hp, 3 Poles

W2ST60354 MFG #: W2ST60354
$10,361.10 / EA
Estimated Delivery 7 to 10 Business Days
  • Manufacturer: Eaton
  • Type: Enclosed Heavy Duty Non-Fusible
  • Voltage Rating: 120/240/480/600
  • Amperage Rating: 60
  • Horsepower: 3 hp at 120 VAC/7.5 hp at 240 VAC/20 hp at 480 VAC/25 hp at 600 VAC at 1-Phase/7.5 hp at 120 VAC/15 hp at 240 VAC/30 hp at 480 VAC at 3-Phase
  • Phase: 1/3
  • Number of Poles: 3
  • Enclosure Type: NEMA 3/12
  • Dimensions: 11-3/4 in L x 7-1/4 in W x 20-1/16 in H
  • Material: Copper Free Aluminum
  • Brand: Crouse-Hinds
Crouse-Hinds Enclosed Switch, Heavy Duty Non-Fusible Raintight, Series: W2ST, 120/240/480/600 VAC, 60 A, 3 hp, 7-1/2 hp, 15 hp, 20 hp, 25 hp, 30 hp, 3 Poles, NEMA 3/12, Pole Mount, Lug Terminal, 11-3/4 in L x 7-1/4 in W x 20-1/16 in H, Copper Free Aluminum
  • Enclosed devices are unfused, factory sealed motor circuit switches
  • Exceeds NEC® wiring end room requirements for ease of wiring
  • The cover is interlocked with the body and operating mechanism to prevent the opening of the enclosu
  • RSWP factory sealed industrial control switch, no external seals are required
  • The cover is interlocked with the body and operating mechanism to prevent the opening of the enclosu
  • Mounting lugs may be rotated 90 deg or moved to the vertical centerline portion for pole mounting
  • Side hinged covers are retained in a closed position by compression spring draw-pull catches, which
  • Mounting lugs may be rotated 90 deg or moved to the vertical centerline portion for pole mounting
  • Side hinged covers are retained in a closed position by compression spring draw pull catches, which
  • The switch operating handle may be padlocked in the On or Off position with up to three padlocks
  • 3 hp at 120 VAC, 7.5 hp at 240 VAC, 20 hp at 480 VAC, 25 hp at 600 VAC, 7.5 hp at 120 VAC, 15 hp at
  • The switch operating handle may be padlocked in the ON/OFF position with up to three padlocks
Enclosed devices are unfused, factory sealed motor circuit switches
Exceeds NEC® wiring end room requirements for ease of wiring
The cover is interlocked with the body and operating mechanism to prevent the opening of the enclosure, except when the switch is in the OFF position
RSWP factory sealed industrial control switch, no external seals are required
The cover is interlocked with the body and operating mechanism to prevent the opening of the enclosure, except when the switch is in the off position
Mounting lugs may be rotated 90 deg or moved to the vertical centerline portion for pole mounting
Side hinged covers are retained in a closed position by compression spring draw-pull catches, which permit the opening or closing of the cover without tools
Mounting lugs may be rotated 90 deg or moved to the vertical centerline portion for pole mounting
Side hinged covers are retained in a closed position by compression spring draw pull catches, which permit the opening or closing of the cover without tools
The switch operating handle may be padlocked in the On or Off position with up to three padlocks
3 hp at 120 VAC, 7.5 hp at 240 VAC, 20 hp at 480 VAC, 25 hp at 600 VAC, 7.5 hp at 120 VAC, 15 hp at 240 VAC, 30 hp at 480 VAC power rating
The switch operating handle may be padlocked in the ON/OFF position with up to three padlocks