Schneider Electric TeSys™ D LC1D096F7 LC1D D-Line IEC Contactor With Protective Cover, 110 VAC V Coil, 25 A, 3NO Contact, 3 Poles

LC1-D096F7 MFG #: LC1D096F7
Requires Quote
Schneider Electric TeSys™ D IEC Contactor, LC1D D-Line, 110 VAC Coil, 25 A Maximum Load Current, 7-1/2 hp Coil, 3 Pole, 50/60 Hz, 1.56/0.2 W, 3NO, 1NO-1NC Auxiliary Contacts, 9 A at 600 VAC Contact, Ring Tongue, Lug Terminal, Open, 15000000 Cycles Operating Cycles, -4 to 140 deg F Operating, Surface Mount, 1.77 in W x 3.39 in D x 3.03 in H
QTY
  • 6 kV conforming to IEC 60947 rated impulse withstand voltage
  • III overvoltage category
  • 25 A at 140 deg F power circuit, 10 A at 140 deg F signaling circuit conventional free air thermal c
  • 250 A at 440 V power circuit conforming to IEC 60947 rated breaking capacity
  • 20 A gG at 690 V coordination type 2-power circuit, 25 A gG at 690 V coordination type 1 power circu
  • 2.5 MOhm at 50 Hz, Ith 25 A power circuit average impedance
  • 12 to 22 ms closing/4 to 19 ms opening operating time
  • 3600 cycles/hr at 140 deg F operating rate
  • Without built-in suppressor module coil technology
  • 2 to 3 W at 60 Hz heat dissipation
  • 70 VA at 68 deg F 50/60 Hz inrush power
  • 7.5 VA at 68 deg F 60 Hz/7 VA at 68 deg F 50 Hz hold-in power consumption
  • 25 to 400 Hz signaling circuit frequency
  • 5 mA minimum switching current
  • 17 VAC signaling circuit minimum switching voltage
  • 1.5 ms on energization between NC and NO contacts/1.5 ms on de-energization between NC and NO contac
  • >10 MOhm signaling circuit insulation resistance
  • TH protective treatment
  • 3 degree of pollution
6 kV conforming to IEC 60947 rated impulse withstand voltage
III overvoltage category
25 A at 140 deg F power circuit, 10 A at 140 deg F signaling circuit conventional free air thermal current
250 A at 440 V power circuit conforming to IEC 60947 rated breaking capacity
20 A gG at 690 V coordination type 2-power circuit, 25 A gG at 690 V coordination type 1 power circuit, 10 A gG signaling circuit conforming to IEC 60947-5-1 associated fuse rating
2.5 MOhm at 50 Hz, Ith 25 A power circuit average impedance
12 to 22 ms closing/4 to 19 ms opening operating time
3600 cycles/hr at 140 deg F operating rate
Without built-in suppressor module coil technology
2 to 3 W at 60 Hz heat dissipation
70 VA at 68 deg F 50/60 Hz inrush power
7.5 VA at 68 deg F 60 Hz/7 VA at 68 deg F 50 Hz hold-in power consumption
25 to 400 Hz signaling circuit frequency
5 mA minimum switching current
17 VAC signaling circuit minimum switching voltage
1.5 ms on energization between NC and NO contacts/1.5 ms on de-energization between NC and NO contacts non-overlap time
>10 MOhm signaling circuit insulation resistance
TH protective treatment
3 degree of pollution