Schneider Electric TeSys™ D LC1D50G6 Non-Reversing IEC Contactor With Protective Cover, 120/690 VAC V Coil, 50/80 A, 3NO Contact, 3 Poles

LC1D50G6 MFG #: LC1D50G6
Requires Quote
Schneider Electric TeSys™ D IEC Contactor, Non-Reversing, Series: LC1D, 120/690 VAC Coil, 50/80 A Maximum Load Current, 40 hp at 575/600 VAC Coil, 3 Pole, 25 to 400 Hz Frequency, 3NO Contact Configuration, 2 Auxiliary Contacts, Screw Clamp Terminal, Open Enclosure, 3600 Cycles/hr Operating Cycles, -5 to 60 deg C Operating, Rail/Surface Mounting, 122 mm H x 55 mm W x 119 mm D Dimensions
QTY
  • Designed to control and provide overload protection to motors rated up to 100 hp at 480 VAC or 125 h
  • New TeSys™ D green increase TeSys™ D range with a new electronic coil with up to 80% less consumptio
  • TeSys™ D green contactor simplify your maintenance services with 90% less references needed
  • TeSys™ D green contactor associated with TeSys™ LR9D electronic overload relay reduces heat generati
  • High fault short circuit current ratings provide the flexibility to select any component, as long as
  • All contactors include built-in auxiliary contacts
  • All screw connections have IP20 finger safe terminals with both North American and international ter
  • Designed for perfect integration in control systems
  • Can be used to create motor starters for any type of application
  • 120 VAC 60 Hz, power circuit, 690 VAC at 25 to 400 Hz
  • 3 hp at 115 VAC 60 Hz 1-phase CSA, 40 hp at 575/600 VAC 60 Hz 3-phase UL, 7-1/2 hp at 230/240 VAC 60
Designed to control and provide overload protection to motors rated up to 100 hp at 480 VAC or 125 hp at 600 VAC, TeSys™ D meets your needs for a majority of motor starter applications
New TeSys™ D green increase TeSys™ D range with a new electronic coil with up to 80% less consumption than TeSys™ D standard AC or DC coil
TeSys™ D green contactor simplify your maintenance services with 90% less references needed
TeSys™ D green contactor associated with TeSys™ LR9D electronic overload relay reduces heat generation and energy consumption up to 50%
High fault short circuit current ratings provide the flexibility to select any component, as long as it meets or exceeds the desired SCCR
All contactors include built-in auxiliary contacts
All screw connections have IP20 finger safe terminals with both North American and international terminal markings
Designed for perfect integration in control systems
Can be used to create motor starters for any type of application
120 VAC 60 Hz, power circuit, 690 VAC at 25 to 400 Hz
3 hp at 115 VAC 60 Hz 1-phase CSA, 40 hp at 575/600 VAC 60 Hz 3-phase UL, 7-1/2 hp at 230/240 VAC 60 Hz 1-phase CSA, 7-1/2 hp at 230/240 VAC 60 Hz 1-phase UL, 3 hp at 115 VAC 60 Hz 1-phase UL, 15 hp at 200/208 VAC 60 Hz 3-phase CSA, 15 hp at 200/208 VAC 6