Littelfuse® MPU-32-00-00 Motor Protection Unit, 65 to 265 VAC, 80 to 275 VDC, NO-NC (3 Form C) Contact

MPU-32-00-00 MFG #: MPU-32-00-00
$3,223.15 / EA
Estimated Delivery 7 to 10 Business Days
Littelfuse® Motor Protection Unit, Series: MPU-32, 65 to 265 VAC, 80 to 275 VDC, 50/60 Hz Frequency, NO-NC (3 Form C) Contact Configuration, Panel Mounting, Wire Clamping Terminal, Onboard Display, 3.8 in H x 3.8 in W x 5.2 in D Dimensions
  • Overload, extends motor life and prevents insulation failures and fires
  • Dynamic thermal model provides protection through starting, running and cooling cycles
  • Communications remotely view measured values and event records, reset trips and access setpoint
  • Ground fault 50G/N, 51G/N prevents catastrophic failures and fires
  • Current unbalance/phase loss/phase reverse prevents overheating due to unbalanced phases
  • RTD temperature protection (MPS-RTD module) for high-ambient or loss-of-ventilation protection
  • Phase loss/phase reverse (current) detects unhealthy supply conditions
  • Overcurrent prevents catastrophic failures and fires, extends motor life
  • Jam prevents motor damage by detecting mechanical jams or excessive loading
  • Undercurrent detects low level or no-load conditions
  • Over temperature (PTC) protection for high-ambient or loss-of-ventilation detection
  • Limits the motor starts per hour to prevent overheating
  • Reduced overcurrent mode minimizes arc flash hazards during maintenance
  • Metering - view measured and calculated parameters with onboard display
  • MPU-CIM - separate current input module to reduce risk of open-CT hazard and for convenient installa
  • Analog output provides means for metering selectable parameters
  • Onboard 100 event recorder for data logging
  • Internal circuits are conformally coated to protect against corrosion and moisture
  • RS/TIA-232 communications
Overload, extends motor life and prevents insulation failures and fires
Dynamic thermal model provides protection through starting, running and cooling cycles
Communications remotely view measured values and event records, reset trips and access setpoint
Ground fault 50G/N, 51G/N prevents catastrophic failures and fires
Current unbalance/phase loss/phase reverse prevents overheating due to unbalanced phases
RTD temperature protection (MPS-RTD module) for high-ambient or loss-of-ventilation protection
Phase loss/phase reverse (current) detects unhealthy supply conditions
Overcurrent prevents catastrophic failures and fires, extends motor life
Jam prevents motor damage by detecting mechanical jams or excessive loading
Undercurrent detects low level or no-load conditions
Over temperature (PTC) protection for high-ambient or loss-of-ventilation detection
Limits the motor starts per hour to prevent overheating
Reduced overcurrent mode minimizes arc flash hazards during maintenance
Metering - view measured and calculated parameters with onboard display
MPU-CIM - separate current input module to reduce risk of open-CT hazard and for convenient installation
Analog output provides means for metering selectable parameters
Onboard 100 event recorder for data logging
Internal circuits are conformally coated to protect against corrosion and moisture
RS/TIA-232 communications