Cooper Wiring Devices Logo

Eaton Wiring Devices SGFD20W SGFD20 Blank Face Blank Face, 125 VAC, 20 A, 2 Poles, 3 Wires, White

SGFD20W MFG #: SGFD20W
$41.68 / EA
Estimated Delivery 7 to 10 Business Days
  • Manufacturer: Eaton
  • Type: Blank Face
  • Series: SGFD20
  • Voltage Rating: 125
  • Amperage Rating: 20
  • Horsepower: 1-1/2
  • Number of Poles: 2
  • Number of Wires: 3
  • NEMA Rating: NEMA 3/3R/4/4X/12/13
  • Enclosure: IP65
  • Temperature Rating: -35 to 66
  • Terminal Type: Back and Side Wired
  • Material: Nylon
  • Color: White
  • Dimensions: 4.75 in L x 2.97 in W
  • Brand: EATON, Eaton Wiring Devices
Eaton Wiring Devices Blank Face, Blank Face, Series: SGFD20, 125 VAC, 20 A, 1-1/2 hp, 2 Pole, 3 Wires, NEMA 3/3R/4/4X/12/13 NEMA Rating, IP65 Enclosure, -35 to 66 deg C, Back/Side Wire Terminal, Nylon, White, 4.75 in L x 2.97 in W Dimensions
  • Straight blade plugs, specification grade
  • Automatic grounding system eliminates need for bonding jumper in grounded metal enclosure, provides
  • Horizontal test/reset button alignment provides larger unobstructed area - buttons are color matched
  • Longer, wider "bridge" strap provides 40% more contact area with wallboard, virtually eliminating fl
  • When downstream receptacles are wired from load side, a 20 amp feed-through rating offers full prote
  • Line-load miswiring protection: GFCIS will not provide power downstream when wired incorrectly
  • Visual indicator lights give quick notification of a tripped or "end of life" condition
  • Automatically self-tests periodically to ensure GFCI protection
  • GFCIS provide state-of-the-art, dependable electrical shock protection in addition to being tested t
  • Back and side wire wiring method
  • Nylon top housing, PVC bottom housing, 0.040 in thick steel, zinc plated strap, NO 8-32 steel, brass
  • Withstands 2000V per UL498 dielectric voltage
  • V2 rated UL94 flammability
  • Current interrupting at full-rated current
  • #14 to 10 AWG terminal accommodation
Straight blade plugs, specification grade
Automatic grounding system eliminates need for bonding jumper in grounded metal enclosure, provides redundant measure of ground continuity where jumper is used
Horizontal test/reset button alignment provides larger unobstructed area - buttons are color matched for superior aesthetics
Longer, wider "bridge" strap provides 40% more contact area with wallboard, virtually eliminating floating installations
When downstream receptacles are wired from load side, a 20 amp feed-through rating offers full protection
Line-load miswiring protection: GFCIS will not provide power downstream when wired incorrectly
Visual indicator lights give quick notification of a tripped or "end of life" condition
Automatically self-tests periodically to ensure GFCI protection
GFCIS provide state-of-the-art, dependable electrical shock protection in addition to being tested to the highest standards to help ensure safety, arrow hart GFCIS will deny power and prevent re-setting if the device is no longer able to provide safe, protected power
Back and side wire wiring method
Nylon top housing, PVC bottom housing, 0.040 in thick steel, zinc plated strap, NO 8-32 steel, brass plated neutral screw nickel plated, ground screw green terminal and ground screws, 0.07 in thick steel terminal clamps
Withstands 2000V per UL498 dielectric voltage
V2 rated UL94 flammability
Current interrupting at full-rated current
#14 to 10 AWG terminal accommodation