Cooper Wiring Devices Logo

Eaton Wiring Devices Arrow Hart TRSGF15W TRSGF Duplex Tamper-Resistant GFCI Receptacle, 125 VAC, 15 A, 2 Poles, 3 Wires, White

TRSGF15W MFG #: TRSGF15W
$39.91 / EA
Estimated Delivery 7 to 10 Business Days
  • Manufacturer: Eaton
  • Type: Duplex Grounding Self-Test Tamper-Resistant, Duplex Tamper Resistant
  • Series: TRSGF
  • Voltage Rating: 125
  • Amperage Rating: 15
  • Frequency Rating: 60
  • Number of Poles: 2
  • Number of Wires: 3
  • NEMA Rating: NEMA 5-15R
  • Grade: Specification
  • Enclosure: IP65
  • Temperature Rating: -31 to 150.8, -35 to 66
  • Terminal Type: Back and Side Wired, Back/Side Wired Screw
  • Material: Polypropylene/PVC/Thermoplastic, Thermoplastic
  • Color: White
  • Dimensions: 4.2 in H x 1.3 in W x 1.27 in D, 4.2 in L x 1.68 in W x 1.27 in D
  • Brand: EATON, Eaton Wiring Devices
Eaton Wiring Devices Arrow Hart GFCI Receptacle, Duplex Tamper-Resistant, Series: TRSGF, 125 VAC, 15 A, 60 Hz Frequency, 2 Pole, 3 Wires, NEMA 5-15R NEMA Rating, IP65 Enclosure, -35 to 66 deg C, Back/Side Wire Terminal, Thermoplastic, White, 4.2 in L x 1.68 in W x 1.27 in D Dimensions
  • If no GFCI protection is present, the receptacle will render itself inoperable and a red indicator l
  • Performs periodic self-tests to ensure integrity of GFCI protection
  • Visual trip indicator light gives quick notification of a tripped or end of life condition
  • Meets and exceeds 10 kA short circuit testing and Underwriters Laboratories (UL) UL943 safety standa
  • Ground termination with back wire clamp provides secure wiring and reduces installation time
  • Automatic grounding system eliminates need for bonding jumper in grounded metal enclosure, provides
  • Tamper resistant shutters help prevent foreign objects from being inserted
  • Line side terminals are backed out and staked for fast installation
  • Horizontal test/reset button alignment provides larger unobstructed area
  • Test and reset buttons are color matched to provide superior aesthetics
  • Tapered back wire openings handle multiple wire sizes and types for applications up to 10 AWG solid
  • When downstream receptacles are wired from load side, a 20A feed through rating offers full protecti
  • Line-load miswiring protection: GFCIs will not provide power downstream when wired incorrectly
  • Tri-combo head terminal and mounting screws
  • Longer, wider bridged strap provides 40% more contact area with wallboard, virtually eliminating flo
  • UL Listed, fully compliant with all latest UL 943 class A GFCI requirements
  • Thermoplastic, polypropylene; nylon 6/6 top housing, thermoplastic, PVC bottom housing, 0.047 in thi
  • Brass/nickel plated steel terminal and ground screws, brass plated steel terminal clamps
  • Tamper resistant models comply with 2014 NEC article 406.12
  • Withstands 2000 V per UL498 dielectric voltage
  • V2 rated UL94 flammability
  • Current interrupting at full-rated current, 0.025 sec class A trip time, Short circuit testing meets
  • #14 to 10 AWG terminal accommodation, Back Wire and Side Wire
If no GFCI protection is present, the receptacle will render itself inoperable and a red indicator light will glow notifying the user there is no power and the device must be replaced
Performs periodic self-tests to ensure integrity of GFCI protection
Visual trip indicator light gives quick notification of a tripped or end of life condition
Meets and exceeds 10 kA short circuit testing and Underwriters Laboratories (UL) UL943 safety standards
Ground termination with back wire clamp provides secure wiring and reduces installation time
Automatic grounding system eliminates need for bonding jumper in grounded metal enclosure, provides redundant measure of ground continuity where jumper is used
Tamper resistant shutters help prevent foreign objects from being inserted
Line side terminals are backed out and staked for fast installation
Horizontal test/reset button alignment provides larger unobstructed area
Test and reset buttons are color matched to provide superior aesthetics
Tapered back wire openings handle multiple wire sizes and types for applications up to 10 AWG solid or stranded wire
When downstream receptacles are wired from load side, a 20A feed through rating offers full protection
Line-load miswiring protection: GFCIs will not provide power downstream when wired incorrectly
Tri-combo head terminal and mounting screws
Longer, wider bridged strap provides 40% more contact area with wallboard, virtually eliminating floating installations
UL Listed, fully compliant with all latest UL 943 class A GFCI requirements
Thermoplastic, polypropylene; nylon 6/6 top housing, thermoplastic, PVC bottom housing, 0.047 in thick steel, zinc plated strap, 0.03 in thick brass line contacts materials
Brass/nickel plated steel terminal and ground screws, brass plated steel terminal clamps
Tamper resistant models comply with 2014 NEC article 406.12
Withstands 2000 V per UL498 dielectric voltage
V2 rated UL94 flammability
Current interrupting at full-rated current, 0.025 sec class A trip time, Short circuit testing meets and exceeds 10 kA, maximum interrupting capacity of 20 A
#14 to 10 AWG terminal accommodation, Back Wire and Side Wire