Crouse-Hinds Arktite® DBR51731 WT100 3 Dust Ignitionproof Grounding Style 1 Raintight Interlocked Receptacle With Enclosed Circuit Breaker, 600 VAC, 100 A, 3 Poles, 3 Wires, Natural

DBR51731 WT100 3 MFG #: DBR51731 WT100 3
$10,771.46 / EA
Estimated Delivery 7 to 10 Business Days
  • Manufacturer: Eaton
  • Type: Dust Ignitionproof Grounding Style 1 Raintight
  • Series: DBR
  • Voltage Rating: 600
  • Amperage Rating: 100
  • Number of Poles: 3
  • Number of Wires: 3
  • NEMA Rating: NEMA 3/9F/9G/12
  • Terminal Type: Copper Free Aluminum
  • Color: Natural
  • Dimensions: 23-1/2 in H x 7-1/4 in W x 8-1/8 in D
  • Brand: Crouse-Hinds
Crouse-Hinds Arktite® Interlocked Receptacle, Dust Ignitionproof Grounding Style 1 Raintight, Series: DBR, 600 VAC, 100 A, 3 Poles, 3 Wires, NEMA 3/9F/9G/12, Copper Free Aluminum Terminal, Natural, 23-1/2 in H x 7-1/4 in W x 8-1/8 in D
  • Receptacles are mechanically interlocked with circuit breakers to provide disconnect means, short ci
  • Receptacles are mechanically interlocked with circuit breakers to provide disconnect means, short ci
  • Enclosures are compact and rectangular in shape permitting close spacing
  • For maximum safety, the spring door receptacle at the bottom is mechanically interlocked with the ci
  • The circuit breaker cannot be closed until the plug is fully inserted and the plug cannot be withdra
  • The circuit breaker cannot be closed until the plug is fully inserted and the plug cannot be withdra
  • Operating handles can be padlocked in either "on" or "off" positions
  • Operating handles can be padlocked in either "on" or "off" positions
  • Breakers are trip-free of the handles and will open under short circuit or overload even if the hand
  • Enclosure is provided with a drilled and tapped conduit opening at top center, equipped with a threa
Receptacles are mechanically interlocked with circuit breakers to provide disconnect means, short circuit protection and thermal time delay overload protection
Receptacles are mechanically interlocked with circuit breakers to provide disconnect means, short circuit protection and thermal time delay overload protection
Enclosures are compact and rectangular in shape permitting close spacing
For maximum safety, the spring door receptacle at the bottom is mechanically interlocked with the circuit breaker operating mechanism
The circuit breaker cannot be closed until the plug is fully inserted and the plug cannot be withdrawn unless the breaker is open
The circuit breaker cannot be closed until the plug is fully inserted and the plug cannot be withdrawn unless the breaker is open
Operating handles can be padlocked in either "on" or "off" positions
Operating handles can be padlocked in either "on" or "off" positions
Breakers are trip-free of the handles and will open under short circuit or overload even if the handle is locked in the "on" position
Enclosure is provided with a drilled and tapped conduit opening at top center, equipped with a threaded-in bushing, the size furnished is 1-1/2 in and removing the bushing permits the use of a 2 in conduit