Crouse-Hinds Arktite® DBR51742 WT100 3 Style 2 Interlocked Receptacle With 3-Pole 100 A Enclosed Circuit Breaker, 600 VAC, 100 A, 4 Poles, 3 Wires

DBR51742 WT100 3 MFG #: DBR51742 WT100 3
$11,105.57 / EA
Estimated Delivery 7 to 10 Business Days
  • Manufacturer: Eaton
  • Type: Style 2
  • Series: DBR
  • Voltage Rating: 600
  • Amperage Rating: 100
  • Number of Poles: 4
  • Number of Wires: 3
  • NEMA Rating: NEMA 3/9FG/12
  • Material: Copper Free Aluminum
  • Dimensions: 23-1/2 in H
  • Brand: Crouse-Hinds
Crouse-Hinds Arktite® Interlocked Receptacle, Style 2, Series: DBR, 600 VAC, 100 A, 4 Pole, 3 Wires, NEMA 3/9FG/12, Copper Free Aluminum, 23-1/2 in H Dimensions
  • Receptacles are mechanically interlocked with circuit breakers to provide disconnect means, short ci
  • Receptacles are mechanically interlocked with circuit breakers to provide disconnect means, short ci
  • Enclosures are compact and rectangular in shape permitting close spacing
  • For maximum safety, the spring door receptacle at the bottom is mechanically interlocked with the ci
  • The circuit breaker cannot be closed until the plug is fully inserted and the plug cannot be withdra
  • The circuit breaker cannot be closed until the plug is fully inserted and the plug cannot be withdra
  • Operating handles can be padlocked in either ON or OFF positions
  • Operating handles can be padlocked in either ON or OFF positions
  • Breakers are trip free of the handles and will open under short circuit or overload even if the hand
  • Enclosure is provided with a drilled and tapped conduit opening at top center, equipped with a threa
  • The size furnished is 1-1/2 in and removing the bushing permits the use of a 2 in conduit
  • The size furnished is 1-1/2 in and removing the bushing permits the use of a 2 in conduit
  • Used in locations where hazardous dusts are present, as in grain processing and handling plants, che
  • Used in locations where hazardous dusts are present, as in grain processing and handling plants, che
  • Used indoors or outdoors in damp, wet or corrosive locations
  • Used indoors or outdoors in damp, wet or corrosive locations
  • 1-1/2 in hub
  • Rain tight
  • Rain tight
  • Natural finish
  • Natural finish
Receptacles are mechanically interlocked with circuit breakers to provide disconnect means, short circuit protection and thermal time delay overload protection
Receptacles are mechanically interlocked with circuit breakers to provide disconnect means, short circuit protection and thermal time delay overload protection
Enclosures are compact and rectangular in shape permitting close spacing
For maximum safety, the spring door receptacle at the bottom is mechanically interlocked with the circuit breaker operating mechanism
The circuit breaker cannot be closed until the plug is fully inserted and the plug cannot be withdrawn unless the breaker is open
The circuit breaker cannot be closed until the plug is fully inserted and the plug cannot be withdrawn unless the breaker is open
Operating handles can be padlocked in either ON or OFF positions
Operating handles can be padlocked in either ON or OFF positions
Breakers are trip free of the handles and will open under short circuit or overload even if the handle is locked in the ON position
Enclosure is provided with a drilled and tapped conduit opening at top center, equipped with a threaded-in bushing
The size furnished is 1-1/2 in and removing the bushing permits the use of a 2 in conduit
The size furnished is 1-1/2 in and removing the bushing permits the use of a 2 in conduit
Used in locations where hazardous dusts are present, as in grain processing and handling plants, chemical plants and certain food processing industries
Used in locations where hazardous dusts are present, as in grain processing and handling plants, chemical plants and certain food processing industries
Used indoors or outdoors in damp, wet or corrosive locations
Used indoors or outdoors in damp, wet or corrosive locations
1-1/2 in hub
Rain tight
Rain tight
Natural finish