Crouse-Hinds Ark-Gard® ENRC12201 ENR Value 2-Gang Dust-Ignitionproof Explosionproof Through-Feed Receptacle Assembly, 125 VAC, 20 A

ENRC12201 MFG #: ENRC12201
$3,037.48 / EA
Estimated Delivery 7 to 10 Business Days
  • Manufacturer: Eaton
  • Type: 2-Gang Dust-Ignitionproof Feed-Through
  • Series: ENR Value
  • Voltage Rating: 125
  • Amperage Rating: 20
  • NEMA Rating: NEMA 5-20R
  • Enclosure: NEMA 7C/7D/9E/9F/9G/12
  • Material: Die Cast Copper Free Aluminum
  • Dimensions: 7-9/16 in L x 8 in W x 6-23/32 in H
  • Brand: Crouse-Hinds
Crouse-Hinds Ark-Gard® Receptacle Assembly, 2-Gang Dust-Ignitionproof Explosionproof Through-Feed, Series: ENR Value, 125 VAC, 20 A, 50 to 400 Hz Frequency, NEMA 5-20R NEMA Rating, NEMA 7C/7D/9E/9F/9G/12 Enclosure, Die Cast Copper-Free Aluminum, 7-9/16 in L x 8 in W x 6-23/32 in H Dimensions
  • Factory sealed chamber encloses the potential arcing components between two explosionproof threaded
  • 1-piece molded gasket seals cover plate and ENP plug when plug is inserted, providing full environme
  • One piece molded gasket seals cover plate and ENP plug when plug is inserted, providing full environ
  • Top-hinged cover design with 45 deg downward angle provides superior protection in damp, wet and dir
  • Top hinged cover design with 45 deg downward angle provides superior protection in damp, wet and dir
  • Field assembly is accomplished with standard tools
  • Use standard EDS back boxes
  • Use standard EDS back boxes
  • Ark-Gard® 2 receptacle incorporates three spring-loaded slide keys that prevent the receptacle face
  • To make the connection, the ENP plug is fully inserted and the receptacle face moved inward by pushi
  • To make the connection, the ENP plug is fully inserted and the receptacle face moved inward by pushi
  • The plug is then rotated, closing the circuit, as rotation begins, the plug becomes locked in the re
  • The plug is then rotated, closing the circuit, as rotation begins, the plug becomes locked in the re
  • In making or breaking the circuit, any resulting electrical arc is confined in the factory sealed ch
  • Dead front interlocked circuit breaking, dust-ignitionproof and raintight
  • Ground fault circuit interrupter
Factory sealed chamber encloses the potential arcing components between two explosionproof threaded joints, these threads are specially coated to guarantee freedom of movement, which ensures ON-OFF action, no additional seals are required
1-piece molded gasket seals cover plate and ENP plug when plug is inserted, providing full environmental protection at the receptacle face
One piece molded gasket seals cover plate and ENP plug when plug is inserted, providing full environmental protection at the receptacle face
Top-hinged cover design with 45 deg downward angle provides superior protection in damp, wet and dirty locations
Top hinged cover design with 45 deg downward angle provides superior protection in damp, wet and dirty locations
Field assembly is accomplished with standard tools
Use standard EDS back boxes
Use standard EDS back boxes
Ark-Gard® 2 receptacle incorporates three spring-loaded slide keys that prevent the receptacle face plate from being rotated until the ENP plug is fully inserted into the receptacle
To make the connection, the ENP plug is fully inserted and the receptacle face moved inward by pushing the plug forward
To make the connection, the ENP plug is fully inserted and the receptacle face moved inward by pushing the plug forward
The plug is then rotated, closing the circuit, as rotation begins, the plug becomes locked in the receptacle and cannot be accidentally disengaged
The plug is then rotated, closing the circuit, as rotation begins, the plug becomes locked in the receptacle and cannot be accidentally disengaged
In making or breaking the circuit, any resulting electrical arc is confined in the factory sealed chamber
Dead front interlocked circuit breaking, dust-ignitionproof and raintight
Ground fault circuit interrupter