Square D™ 2601AG2 Type AG Drum Switch, 600 VAC/250 VDC, 2 hp, 1/4 hp, 1-1/2 hp Power Rating, 3 Poles

2601AG2 MFG #: 2601AG2
Requires Quote
Square D™ Drum Switch, Type AG, Series: 2601, 600 VAC/250 VDC, 2 hp, 1/4 hp, 1-1/2 hp, 2 hp at 200/230/460/575VAC, 1/4 hp at 115/230 VDC, 1-1/2 hp at 115 VAC Contact, 3 Pole, Reversing, Handle, NEMA 1 Enclosure, Flush
QTY
  • Screw clamp terminal connections
  • Reversing drum switches are designed to start and reverse motors by connecting them directly across
  • The devices may be used with squirrel cage motors, one phase motors designed for reversing service a
  • The applications should be such that across-the-line starting of the motors is not objectionable, un
  • Class 2601 drum switches are field convertible from maintained to momentary operation
  • Large movable contact segments are rigidly attached to the main operating shaft
  • They are fully insulated from each other and from the shaft
  • Stationary contact fingers are mounted in polymeric blocks
  • Both movable and stationary contacts are plated for maximum life
  • Extremely accessible terminals are provided for easy wiring, contacts are not replaceable
  • Type a is provided with screw type terminals and type B is provided with pressure wire connector ter
  • The operating mechanism is assembled for maintained position operation, that is when the handle is m
  • The mechanism can be easily converted, with no additional parts needed, to provide spring return to
  • This conversion is accomplished by removing the handle screw and handle, turning the shaft 180 deg a
  • Both the nema type 1 and NEMA type 4 devices offer as standard a 1 piece die cast handle
  • The polymeric NEMA type 1 enclosure is suitable for indoor applications when normal atmospheric cond
  • The nema type 4 enclosure is suitable for applications requiring watertight and dust tight capabilit
  • Two knockouts or openings for 1/2 in conduit entries are located in the bottom plate of the AG/BG ty
  • A single captive screw holds the cover on NEMA type 1 enclosures, while three captive screws hold th
Screw clamp terminal connections
Reversing drum switches are designed to start and reverse motors by connecting them directly across the line
The devices may be used with squirrel cage motors, one phase motors designed for reversing service and series, shunt and compound DC motors
The applications should be such that across-the-line starting of the motors is not objectionable, unless other means is provided for limiting starting current and torque
Class 2601 drum switches are field convertible from maintained to momentary operation
Large movable contact segments are rigidly attached to the main operating shaft
They are fully insulated from each other and from the shaft
Stationary contact fingers are mounted in polymeric blocks
Both movable and stationary contacts are plated for maximum life
Extremely accessible terminals are provided for easy wiring, contacts are not replaceable
Type a is provided with screw type terminals and type B is provided with pressure wire connector terminals
The operating mechanism is assembled for maintained position operation, that is when the handle is moved to the forward or reverse position, it will remain there until moved
The mechanism can be easily converted, with no additional parts needed, to provide spring return to off operation
This conversion is accomplished by removing the handle screw and handle, turning the shaft 180 deg and then replacing the handle and handle screw
Both the nema type 1 and NEMA type 4 devices offer as standard a 1 piece die cast handle
The polymeric NEMA type 1 enclosure is suitable for indoor applications when normal atmospheric conditions prevail
The nema type 4 enclosure is suitable for applications requiring watertight and dust tight capabilities
Two knockouts or openings for 1/2 in conduit entries are located in the bottom plate of the AG/BG types, while two 1/2 in conduit entries with hubs are provided as standard in AW/BW types
A single captive screw holds the cover on NEMA type 1 enclosures, while three captive screws hold the cover on NEMA type 4 enclosures