Drager Pac 6000 H2S (US)

8326368
Requires Quote
Estimated Delivery 7 to 10 Business Days
The single-gas detector Pac 6000 for personal air monitoring is maintenance-free, has a lifetime of 2 years, and is approved according to cCSAus, ATEX, and IECEx for zone 0, T4. The Dräger Sensor XXS H2S LC is used for reliable alerting. The device is delivered with a calibration certificate and instructions for use (10 languages). - tightly closing alligator clip - triple alarm: optical 360° alarm LEDs, acoustic (90 dBA), vibration - gas inlet on the top and on the front - language-neutral display - D-Light (compliance signal) - impact-resistant and robust housing - sensor identification via colored and written markings - easily exchangeable and robust dust filter - event and data logger - exchangeable battery - compatible with Dräger X-dock and Dräger Bump Test Station - US configuration Dräger Sensor XXS H2S LC: - detection limit: 0.4 ppm - resolution: 0.1 ppm - measuring range: 0 to 100 ppm Default settings: - alarm thresholds: A1 = 10 ppm, A2 = 15 ppm - status bump test: quick bump test - operation signal: on (LED) Gas detection instrument: - dimensions: 60 x 84 x 20 mm - weight: 106 g (113 g with clip) - degree of protection: IP68