Crouse-Hinds

Crouse-Hinds Ark-Gard® ENR11202 ENR Value 1-Gang Dead End Dust-Ignitionproof Explosionproof Receptacle Assembly, 125 VAC, 15 A

ENR11202 MFG #: ENR11202
$1,509.96 / EA
Non-Stock Item
  • Amperage Rating: 15 A
  • Country of Origin: US
  • Dimensions: 3-1/2 in L x 8 in W x 6-23/32 in H
  • Enclosure: NEMA 7C/7D/9E/9F/9G/12
  • Manufacturer Name: Eaton
  • Material: Die Cast Copper-Free Aluminum
  • NEMA Rating: NEMA 6-20R
  • Series: ENR Value
  • Type: 1-Gang Dead End Dust-Ignitionproof Explosionproof
  • Voltage Rating: 125 VAC
Ark-Gard ENC connectors, ENP plugs and ENR receptacles from Eaton Crouse-Hinds Division make it safe and easy to bring power wherever it is needed. Connectors provide versatility for making cordsets for connecting portable devices in both hazardous and non-hazardous locations. Ark-Gard plugs and receptacles are used with portable electrical equipment such as compressors, tools, lighting systems and similar devices when power requirements do not exceed 20 amperes. They are also used in areas made hazardous by the presence of flammable vapors and gases or combustible dusts.
  • Standards
  • Item Features
  • Application
UL File No. 1010|CEC Certified|Class I Div 1, 2 Groups B/C/D Class II, Div 1, 2 Groups G|Class III|CSA C22.2|NEC Certified|Class I Div 1, 2 Groups B/C/D, Class II, Div 1, 2 Groups F/G, Class III|UL File No. 1203|UL File No. 943
  • Factory sealed chamber encloses the potential arcing components between two explosionproof threaded joints, these threads are specially coated to guarantee freedom of movement, which ensures On-Off action, no additional seals are required
  • One-piece molded gasket seals cover plate and ENP plug when plug is inserted, providing full environmental protection at the receptacle face
  • Top hinged cover design with 45 deg downward angle provides superior protection in damp, wet and dirty locations
  • Field assembly is accomplished with standard tool
  • Use standard EDS back boxes
  • Ark-Gard® 2 receptacle incorporates three spring loaded slide keys that prevent the receptacle face plate from being rotated until the ENP plug is fully inserted into the receptacle
  • To make the connection, the ENP plug is fully inserted and the receptacle face moved inward by pushing the plug forward
  • The plug is then rotated, closing the circuit, as rotation begins, the plug becomes locked in the receptacle and cannot be accidentally disengaged
  • In making or breaking the circuit, any resulting electrical arc is confined in the factory sealed chamber
  • Dead front interlocked circuit breaking, dust-ignitionproof and rain tight
  • Ground fault circuit interrupter
Industrial Facilities and Factories, Facility, Power Distribution and Control Applications