IDEAL® Test-Pro® 61-340 340 Digital Multimeter, 4 to 600 VAC, 400 mV to 600 VDC, 400 uA to 10 A, 4 kOhm to 40 MOhm, LCD Display
61-340
MFG #: 61-340
$127.28
/ EA
Non-Stock Item
- Request For Quote: No
IDEAL® Test-Pro® Digital Multimeter, Series: 340, 4 to 600 VAC, 400 mV to 600 VDC, 400 uA to 10 A, 10 Hz to 4 MHz Frequency, 4 kOhm to 40 MOhm Resistance, Safety Rating: CAT III 600 VAC/VDC, 400 nF to 4000 uF Capacitance, 73 deg C +/- 41 deg C <75% RH Accuracy, LCD Display, 61-340 200 hr, 61-342 150 hr 9 VDC NEDA 1604 Alkaline Battery, Yes Diode Test, 7 in H x 3.5 in W x 1.9 in D Dimensions, 32 to 140 deg F at <75% RH, -4 to 140 deg F at <80% RH without Battery Storage Temperature
- Measures AC/DC voltage, AC/DC current, resistance, capacitance, temperature, frequency and audible c
- Relative mode, backlight
- Minimum maximum data hold
- Low battery indicator
- Auto power off
- 0.7 V RMS, >1 MHz 5 V RMS sensitivity
- 0.5 A/500 VAC (#F-340), 10 A/1000 VAC (#F-341) fuse
- 400 mVDC/4/40/400 VDC at +/-(0.5% +5), 600 VDC at +/-(1% +3) DC voltage accuracy
- F-340 0.500 A (500 VAC) 6.350 x 32 mm fuse, F-341 10 A (1000 VAC) 10 x 38 mm fuse, 9 VDC battery, TL
- 400 mVAC/4/40/400/600 VAC at +/-(1.5% +5) AC voltage accuracy
- 400/4000 mic A, 40/400 mA at +/-(0.5% +5), 4/10 A at +/-(1.5% +5) DC current accuracy
- 400/4000 mic A at +/-(1.5% +5), 40/400 mA at +/-(2% +5), 4/10 A at +/-(2.5% +5) AC current accuracy
- The beeper turns on less than 25 Ohm and turns off at >120 Ohm continuity
- -58 to 1500 deg F at +/-(3% +5), -50 to 800 deg C at +/-(3% +3) temperature measurement accuracy
- 10 MOhm for VAC and VDC input impedance
- 10/100 Hz/1/10/100 kHz/1/10 MHz at +/-(0.1% +3) frequency measurement accuracy
Measures AC/DC voltage, AC/DC current, resistance, capacitance, temperature, frequency and audible continuity
Relative mode, backlight
Minimum maximum data hold
Low battery indicator
Auto power off
0.7 V RMS, >1 MHz 5 V RMS sensitivity
0.5 A/500 VAC (#F-340), 10 A/1000 VAC (#F-341) fuse
400 mVDC/4/40/400 VDC at +/-(0.5% +5), 600 VDC at +/-(1% +3) DC voltage accuracy
F-340 0.500 A (500 VAC) 6.350 x 32 mm fuse, F-341 10 A (1000 VAC) 10 x 38 mm fuse, 9 VDC battery, TL-100 test leads with alligator clips, C-290 nylon carrying case replacement parts
400 mVAC/4/40/400/600 VAC at +/-(1.5% +5) AC voltage accuracy
400/4000 mic A, 40/400 mA at +/-(0.5% +5), 4/10 A at +/-(1.5% +5) DC current accuracy
400/4000 mic A at +/-(1.5% +5), 40/400 mA at +/-(2% +5), 4/10 A at +/-(2.5% +5) AC current accuracy
The beeper turns on less than 25 Ohm and turns off at >120 Ohm continuity
-58 to 1500 deg F at +/-(3% +5), -50 to 800 deg C at +/-(3% +3) temperature measurement accuracy
10 MOhm for VAC and VDC input impedance
10/100 Hz/1/10/100 kHz/1/10 MHz at +/-(0.1% +3) frequency measurement accuracy