GE TED136070 Type TED Core E Mid Tier Molded Case Circuit Breaker With Cu/Al Load Lug, 600 VAC, 70 A, 14 kA Interrupt, 3 Poles, LI/Non-Interchangeable Thermal Magnetic Trip

TED136070 MFG #: TED136070
Requires Quote
Non-Stock Item
  • Actuator Type: Pivot/Toggle Handle
  • Amperage Rating: 70 A
  • Connection Type: Load Lug
  • Dimensions: 6-5/16 in H x 4-1/8 in W x 3-3/8 in D
  • Frame: E150
  • Frequency Rating: 50/60 Hz
  • Interrupt Rating: 14 kA
  • Manufacturer Name: ABB
  • Material: Plastic
  • Mounting Type: Bolted-On
  • Number of Poles: 3
  • Phase: 3
  • Temperature Rating: 10 to 50 deg C
  • Trip Type: LI/Non-Interchangeable Thermal Magnetic
  • Type: Type TED Core E Mid Tier
  • Voltage Rating: 600 VAC
  • Wire Size: 4 to 3 AWG
The E150 product line consists of Thermal Magnetic Circuit Breakers, Magnetic Circuit Breakers and Molded Case Switches rated up to 150 A and 600 VAC. Catalog numbers include the complete breaker or switch. The WL catalog number suffix indicates that the devices come with Cu/Al line and load lugs.
  • Application
  • Item Features
  • Standards
Industrial, Switchboards, Motor Control Centers and Lighting, Power and Customized Control Panelboards, Electrical Distribution and Control Applications
  • Molded case is molded from high mechanical and high dielectric strength engineered plastic
  • Trip indication is shown by handle position midway between ON and OFF, to reset the trip mechanism, move the handle to extreme OFF, then to ON position
  • Quick make, quick break, trip free mechanism minimizes arcing during breaker operation, contacts cannot be ''teased'' into position
  • Trip free mechanism is independent of manual handle control, the breaker trips under short circuit or overload, even though the operating handle is held in ON position
  • VERIFIERâ„¢ "Twist-to-Trip" and ''Push-to-Trip'' mechanically simulates over current tripping through actuation of linkages not operated by the ON-OFF handle
  • Common trip bar assures instant disconnect of all conductors when an overload or short circuit occurs on any one conductor in the circuit or an accessory trip device operates
  • Silver alloy contacts combine the conductive properties of silver with other elements for clean, positive electrical contacting, pitting and burning are minimized for longer contact life
  • Arc chutes of heat absorbing, insulating material and metal grid plates quickly ''extinguish'' arcs
  • UL listed lugs for copper or aluminum cable, at full frame rating, easy access and simple, straight-in wiring
  • Proven reliability
  • Provide cost effective solutions
  • Multiple types to fit in your application
  • 10 kA at 125 VDC, 10 kA at 250 VDC, 10 kA at 500 VDC, 14 kA at 600 VAC, 18 kA at 120/240 VAC, 18 kA at 240 VAC, 18 kA at 277 VAC, 18 kA at 480 VAC interrupt rating
ARRA Compliant|Buy American Act Compliant|RoHS Compliant|UL 489 File No.E11592|CSA File No. LR57114|Federal Specification WC375